For industrial and commercial sites

Keep sites and people working through hotter summers.

Heat is raising cooling costs and stressing people and plant. Find your site's weak spots in a free 5-minute self-check, get a dated 30-day plan, and soon, a heat twin that watches the forecast for you.

  • Runs in your browser
  • Vendor-independent
  • Based on public standards
  • No cookies or trackers
3 days to prepare

Heat twin · example warehouseFictional site · synthetic forecast

Coming soon
Base score58/100High
+15
Forecast-adjusted73/100High
HEAT EPISODE 4–9 JUL 30° 25° 1 Jul8 Jul15 Jul

Heat episode expected 4–9 Jul, peak about 33 °C. Five actions moved before the heat.

  • 3 JulBeforeCheck which façades get afternoon sun and whether there is outside shading.
  • 4 JulHeat dayActivate the heat plan: confirm who decides on hours and breaks.
  • 10 JulPlanNote the roof colour, material and age, and when it is due for maintenance.
Example heat twin for a fictional warehouse, run on a synthetic forecast. Same scoring as the free self-check.

Why now

Heat is now an everyday workplace risk

Europe is the fastest-warming continent, and 2024 was its warmest year on record. Work, plant and stock feel it first, often before a thermostat does.

2.4 bn+

workers likely exposed to excessive heat during their work: 70.9% of the global workforce.

ILO, 2024
22.87 m

occupational injuries a year attributable to excessive heat.

ILO, 2024
18,970

work-related deaths a year attributable to excessive heat.

ILO, 2024
2024

Europe's warmest year on record, on the fastest-warming continent.

C3S & WMO, 2025
  • Heat strain on people and work

    Radiant heat, dark roofs and physical work push strain up before thermostats trigger.

  • Cooling load and energy pressure

    Chillers run flat out fighting avoidable solar gain, driving up peak electricity demand.

  • Asset and stock degradation

    Thermal load trips switchgear and threatens temperature-sensitive goods in storage.

Sources: ILO, Ensuring safety and health at work in a changing climate (22 April 2024; worker figures for 2020). Copernicus Climate Change Service and WMO, European State of the Climate 2024 (15 April 2025).

How it works

From a 5-minute check to a plan that moves with the weather

One set of 15 questions, one transparent scoring model, three ways to use it.

  1. 1Free

    Heat-risk self-check

    5 minutes · 15 questions · in your browser

    An overall score, four pillar scores, your three biggest gaps and the employer duties that apply.

    Start the check
  2. 2PDF · one site

    Heat-Risk Readiness Report

    7–9 pages · €147.93 excl. VAT

    An executive brief, a finding for every answer, a week-by-week 30-day plan and the questions to ask suppliers.

    See sample reports
  3. 3Coming soon

    Heat twin

    Your site's own heat-risk model

    Watches the 15-day forecast for your location and moves your plan forward when a heat episode is on the way.

    Try the demo

Free · one site

Heat-risk self-check

Fifteen short questions about one site. See where heat gets in, where it builds up, and who it affects.

  • Score and risk band, plus four pillar scores: building, cooling, people and preparedness.
  • Your three biggest gaps, each explained, and all 14 findings answer by answer.
  • The Arbowet employer duties your answers trigger.
  • Private by design. Your 15 answers stay in your browser and are never sent anywhere.
How scoring works

Four pillars: Building and envelope, Cooling and equipment, People and work, and Preparedness. Weights are transparent, judgement-based relative weights (36 maximum points across 14 scored questions; question 15 sets timing). Bands: 0–24 Low · 25–49 Moderate · 50–74 High · 75–100 Critical. The same answers always give the same result, in the self-check, the paid report and the heat twin.

The questions describe the site; please do not enter names or health details.

Your site, 15 questions

Answers stay in your browser
No time? See a result for an example site (matches our sample PDFs):
Start the free self-check
0 of 15 questions answered Answer all 15 to calculate your site score

Water is the other half of climate resilience. Try the water resilience check.

Scores sites, not people. Not engineering, legal or health advice.

Paid · for businesses

Heat-Risk Readiness Report

The same 15 questions as the free self-check, turned into a 7-to-9-page PDF report for one site that you can share with management, staff representatives and suppliers.

  • One-page executive briefScore, risk band, four pillar scores and your top three gaps.
  • A finding for every answerAll 14 scored answers explained one by one.
  • Week-by-week 30-day planLow-cost actions ordered by severity, with checkboxes.
  • Independent options checklist and supplier questionsSolution categories for your gaps; no product rankings or paid placements.
  • Tailored employer heat dutiesArbowet, Arbobesluit and WOR duties triggered by your answers.

Sample PDF reports (fictional example data)

Sources and method

Based on public standards and sources: Arbowet, Arbobesluit, RIVM, KNMI, Klimaateffectatlas, EU-OSHA, ISO 7243. The same answers always produce the same report. No fabricated benchmarks, no speculative cost or payback numbers, no vendor rankings.

Related: heat collection on Aspiration Platform.

One site · PDF report

€147.93

excl. VAT (€179 incl. 21% VAT)

  • Executive brief and 14 findings
  • Week-by-week 30-day plan
  • Supplier questions per gap
  • Employer duties for your answers

For businesses only; EU reverse charge outside NL. Not yet on sale. Terms

Scores sites, not people. Not engineering, legal or health advice.

Coming soon · for businesses

Heat twin: your site's own heat-risk model, kept current with the forecast

The same 15 answers and the same scoring as the self-check, plus your site's location. When a heat episode is forecast near your site, the twin flags it, shows how many days you have, and re-dates your 30-day plan.

Forecast scenario
Site answers

Finish the self-check above to run the twin on your own answers. They stay in this browser tab.

Demo only: the three forecasts are synthetic examples, not real weather data, and the sites are fictional. Day 1 is shown as 1 July. The scores and dates come from the same fixed rules the heat twin will use. Follow official weather warnings on the day.

  • Built from your self-checkThe same 15 answers and the same scoring as the self-check, plus your site's location.
  • Watches the 15-day forecastWhen a heat episode is forecast near your site, the twin flags it and shows how many days you have.
  • A dated plan that moves with the weatherActions you can still take before the heat move forward. Building measures wait until after it.
  • Email digest and a private dashboardOnly when something changes. No account to manage, and never personal health data.
How the twin decides: the published rules

Every forecast day is classed by its maximum and minimum temperature:

≥ 25 °Cwarm day
≥ 30 °Chot day
≥ 20 °Ctropical night (minimum)
  • Heat episode: 3 or more warm days in a row including at least one hot day, or a hot day with a tropical night.
  • Forecast points: up to 15, larger when the site already has cooling, people or preparedness gaps. They are shown next to the base score, never mixed into it.min(15, round((2·days + 3·hot days + 2·tropical nights) · (0.5 + 0.5·sensitivity)))
  • Re-dated plan: quick actions (service, heat plan, shading, work, monitoring) are due the day before the heat starts; heat-day steps are placed on each episode day; building measures (roof, glazing, envelope, location) move to after the episode.
  • Confidence: an episode starting 7 or more days ahead is shown as “possible (may change)”; nearer ones as “expected”.
Where the forecast comes from

The heat twin is designed to use ECMWF Open Data: the 15-day forecast of the European Centre for Medium-Range Weather Forecasts, published under a CC BY 4.0 licence. The twin reads the nearest grid point (about 25 km) to your site and reduces it to daily maximum and minimum temperatures. It works for any location in the world, in °C, and is not an official forecast or warning. The demo above uses synthetic forecasts, not ECMWF data.

What “AI” honestly means here

The scores and the plan are calculated by fixed, published rules from your answers and the forecast. No machine-learning model decides anything. An optional AI-written plain-language summary may be offered later: off by default, labelled “AI-written”, and never allowed to change a score or a date.

Scores sites, not people. Not engineering, legal or health advice.

Tell me when the heat twin is available

We will start with a small pilot of businesses. One email when it opens, nothing else.

Only your email address and this consent tick are sent. See our privacy notice.

Want to be in the pilot? Tell us about your site.

Order of measures · Cooling Trias

The 4-step heat hierarchy

Sizing mechanical cooling before reducing heat gains locks a facility into higher peak electricity loads and faster equipment wear.1 Work through the steps in order.

  1. 1Block solar gain before it crosses the roof or glass.
  2. 2Contain internal heat at the source.
  3. 3Flush and cool efficiently, sized for the reduced load.
  4. 4Sense, plan and protect people with clear triggers.
Where heat enters and builds up in a building Cross-section of a commercial building. The sun heats a dark roof and unshaded glazing (step 1). A process oven radiates heat inside (step 2). Cool night air enters low and leaves through a roof vent (step 3). A sensor and a heat plan protect the person working on the mezzanine (step 4). Glazing Dark roof Process heat Night air Sensor 1 2 3 4
Tap a number to open that step.
Step 1 · Building envelope and surroundings

Keep solar radiation outside the envelope first

A dark bitumen, EPDM or metal roof gets very hot in summer sun, radiating heat down into top floors and mezzanines while accelerating membrane ageing. Similarly, unshaded south and west glazing admits direct short-wave solar radiation that traps heat indoors.

  • Cool-roof coatings and light membranes: high solar reflectance and thermal emittance reduce peak roof surface temperature.
  • External solar shading: screens, brise-soleil, louvres and overhangs stop solar gain before it crosses the glazing (Arbobesluit art. 6.4).
  • Solar-control glazing and films: lower total solar energy transmittance (g-value) on existing façades and rooflights.
  • Site microclimate: unpaving, green or blue-green roofs and tree shade around paved industrial yards (Klimaateffectatlas hotspots).

Truthful watch-outs and supplier questions

  • Aged vs. initial reflectance: dirt and weathering reduce roof reflectance over time. Always ask for aged solar reflectance and thermal emittance tested under recognised standards (e.g. CRRC / ECRC).
  • Roof warranty and PV synergy: confirm in writing that coatings do not void the existing waterproofing warranty. Cooler roof surfaces can modestly benefit bifacial or rooftop PV electronics.
  • Glazing thermal stress: applying dark or reflective film to existing double or triple glazing without a thermal-stress check can crack sealed units.

1 IEA, The Future of Cooling; EU-OSHA workplace heat guidance.

Independence

How we earn, and our independence pledge

You pay Humanity Solutions for the Heat-Risk Readiness Report (€147.93 excl. VAT), or for site-specific advisory work we agree and quote in writing before starting. We do not sell or install products.

  • No rankings for saleNo product rankings, paid placements or sponsored answers in the self-check, report or twin.
  • Fees disclosed firstIf a vendor may pay us a referral fee, we tell you in writing before you decide.
  • At least two optionsWhere more than one suitable option exists, we show you at least two.
  • Never added to your quoteVendors warrant that a referral fee is never added to your price (most-favoured pricing).
Supplier introductions

If you later ask us to introduce you to a supplier and you choose to buy from that supplier, the vendor may pay us a referral fee. Under our standard vendor referral terms (PDF), vendors warrant that the referral fee is never added to your quote (most-favoured pricing). We always disclose any referral fee to you before you decide, we show at least two options where they exist, and our advice never depends on who pays us.

Six technical areas we examine across sites
  • Thermal coatings. Cool-roof and reflective barrier coatings timed with roof maintenance.
  • Insulation. Roof and wall envelope upgrades and EN ISO 12241 removable jackets on hot pipes, valves and plant.
  • Architectural measures. External solar shading, brise-soleil, louvres, rooflight shading and solar-control glazing film.
  • HVAC, night purge and active cooling. Free night cooling, zoning, spring commissioning and right-sized cooling plant.
  • Monitoring and sensing. Open-export temperature loggers, WBGT work-zone sensing (ISO 7243) and thermal imaging surveys.
  • People and planning. Written heat plans with KNMI or temperature triggers, work-rest schedules and Arbowet / RI&E input.

FAQ

Questions

Something else? Ask us directly. A person reads every message.

Do you sell or install cooling or coating products?

No. We help you diagnose your heat exposure, prioritise passive and operational measures first, and know what to ask suppliers. Independent vendors supply and install.

How do you earn money?

You pay for the Heat-Risk Readiness Report (€147.93 excl. VAT) or for advisory work we quote in writing. If you choose a vendor through our introduction, that vendor may pay us a referral fee. We tell you in writing before you decide, and our contract with vendors prohibits them from marking up your price.

What is a heat twin, and when is it available?

A heat twin is a small model of one site's heat risk that stays current: your 15 self-check answers, your site's location, and the 15-day weather forecast for that spot. When a heat episode is forecast, it flags it and re-dates your 30-day plan, with an email only when something changes. It is in development and will start with a small pilot. Try the demo or ask to be notified.

Is the heat twin “AI”?

The scores, dates and plan come from fixed, published rules, not from machine learning, and the base score never changes with the weather. An optional AI-written plain-language summary may be offered later; it will be off by default, clearly labelled, and never changes a score or a date.

Does it work outside the Netherlands?

The heat twin is designed to be country-neutral: any location, temperatures in °C, and no country-specific legal text in its output. The self-check and the paid report also list Dutch employer duties (Arbowet), because that is where we started.

Why are there no cost savings or ROI percentages in the self-check or report?

Because generic payback percentages from a 15-question questionnaire would be guesswork. Energy savings and temperature drops depend on your exact roof build-up, internal loads, local weather, ventilation rates and tariff structure. Instead of invented numbers, we give you a transparent score, a 30-day action plan, and the exact technical questions to ask installers and engineers.

Is the self-check or report engineering, legal or health advice?

No. Both are structured diagnostic tools based on public guidance (RIVM, KNMI, Klimaateffectatlas, EU-OSHA, ISO 7243, Arbowet). They score sites, not individuals, and do not replace a site inspection by a structural or HVAC engineer, occupational hygienist (arbodienst) or legal counsel.

What happens to my data?

This site uses no cookies, no analytics and no third-party trackers. Your 15 self-check answers run entirely in your browser and are never sent to us (unless you choose to paste your summary into an email draft); the heat twin demo also runs in your browser. We never pass your details to a vendor without your prior consent for that specific introduction. See our privacy notice.

Contact

Book a heat-risk conversation

The initial conversation is free. Tell us about your facility and the heat pressures you see, or carry over your self-check summary.

  • A person reads every message and replies by email to set up a short call or issue a Readiness Report.
  • Nothing is sent behind the scenes. The form opens a draft in your own email app; you decide whether to send it.
  • Prefer plain email? Write to connectwithus@humanitysolutions.net.

Opens your email app with a pre-filled draft to connectwithus@humanitysolutions.net. Nothing is transmitted behind the scenes when you click this button: you review the draft in your email client and decide whether to send it. Humanity Solutions (KvK 71110178) uses messages only to reply. See our privacy notice.

Suppliers

For vendors

Supply heat-protection products, engineering or sensing for commercial or industrial sites? We may introduce proven fits to clients who ask.

Ask about vendor partnership

Opens your email app with a draft to connectwithus@humanitysolutions.net, subject “Heat vendor partnership”. Nothing is sent automatically from this page.